COMMERCIAL ROOFING PRODUCTS
Music City Metal Roofing
Call Us!
(615) 672-8917
Commercial
Products:

Magna-Loc
Seam-Loc
Snap-Loc
Vertical Seam
ClipLoc
T-Span
Specifications:
Architectural/structural flat pan standing seam panel
16" and 18" panel coverage, 2" rib height
Gauges: 24ga standard, 22ga optional
Minimum roof slope: 1/2:12
Factory applied side lap sealant
Integral mechanically seamed side lap seam
Concealed clip designed for thermal movement
Accommodates 1/2" to 6" blanket insulation
Applies over open framing or solid substrate
Finishes: Kynar 500 (PVDF), MS Colorfast45, and ACG
Specifications:
Structural trapezoidal standing seam panel
24" panel coverage, 2-11/16" rib height
Gauges: 24ga standard, 22ga optional
Minimum roof slope: 1/4:12
Factory applied side lap sealant
Pittsburgh double flat locking mechanically seamed side lap
Concealed clip designed for thermal movement
Accommodates 1/2" to 6" blanket insulation
Applies over open framing or solid substrate
Finishes: Kynar 500 (PVDF), MS Colorfast45 and ACG
Magna-Loc
Seam-Loc
Snap-Loc
Vertical Seam
ClipLoc
T-Span
Specifications:
Structural trapezoidal standing seam panel
24" panel coverage, 3" rib height
Gauges: 24ga standard, 22ga optional
Minimum roof slope: 1/4 :12
Factory applied side lap sealant
Snap together panel system
Concealed clip designed for thermal movement
Accommodates 1/2" to 6" blanket insulation
Applies over open framing or solid substrate
Finishes: Kynar 500 (PVDF), MS Colorfast45, and ACG
Specifications:
Architectural/structural integral standing seam panel
12", 16", and 18" panel coverage, 1-3/4" rib height
Gauges: 26ga and 24ga standard, 22ga optional
Snap together panel system, minimum roof slope:3:12
Factory applied side lap sealant
Concealed clip designed for thermal movement
Accommodates up to 4" blanket insulation
Applies over open framing or solid substrate
Finishes: Kynar 500 (PVDF), MS Colorfast45 and ACG
Specifications:
Architectural/structural integral standing rib roof system
Snap together panel system
16" panel coverage, major rib: 8" centers, 1-5/8" rib height
Gauges: 26ga, 24ga standard, and 22ga optional
Minimum roof slope 1:12
Applies over open framing or solid substrate
Concealed clip designed for thermal movement
Accommodates up to 4" blanket insulation Finishes: Kynar
500 (PVDF), MS Colorfast45 and ACG
Architectural/structural flat pan standing seam panel
16" and 18" panel coverage, 2" rib height
Gauges: 24ga standard, 22ga optional
Minimum roof slope: 1/2:12
Factory applied side lap sealant
Integral mechanically seamed side lap seam
Concealed clip designed for thermal movement
Accommodates 1/2" to 6" blanket insulation
Applies over open framing or solid substrate
Finishes: Kynar 500 (PVDF), MS Colorfast45 and ACG
Custom cut to length.
45 year warranty on paint
Non warranty materials available for that low budget job.
Green roofing with Energy Star
Cool roof rated colors
Testing:
UL 263, Fire Resistance Rating
UL 2218 Class 4 Impact Resistance
UL-790, Class A Fire Resistance
Rating
ASTM E-1680 Air Penetration
ASTM E-1646 Water Infiltration
UL 580, Class 90 Uplift, Construction
#240
ASTM E-330, Uniform Static Air
Pressure Difference
CEGS-07416 US Army Corps of
Engineers Rated-ASTM E-1592

Testing:
UL 263, Fire Resistance Rating
UL 2218 Class 4 Impact Resistance
UL-790, Class A Fire Resistance
Rating
ASTM E-283 Air Infiltration
ASTM E-331 Water Penetration
UL 580, Class 90 Wind Uplift,
Construction #197 and 197A
CEGS-07416 US Army Corps of
Engineers Rated-ASTM E-1592

Testing:
UL-263, Fire Resistance Rating
UL-2218 Class 4 Impact Resistance
Factory Mutual Approved Class 1-90
UL-790 Class A Fire Resistance
Rating
ASTM E-1680 Air Penetration
Approved
ASTM E-1646 Water Infiltration
Approved
CEGS-07416 US Army Corps of
Engineers Rated-ASTM E-1592
UL 580, Class 90 Wind Uplift,
Construction Number 506, 506A,
506B
Testing:
UL 263, Fire Resistance Rating
UL 2218 Class 4 Impact Resistance
Dade County Approved
UL 790, Class A Fire Resistance
Rating
ASTM E-1680 Air Infiltration
ASTM E-1646 Water Penetration
CEGS-07416 US Army Corps of
Engineers Rated-ASTM E-1592
UL 580, Class 90 Wind Uplift,
Construction Numbers 254, 255, 261,
303, 342, 343, 436, 445, 446, 447,
448

Testing:
UL-2218 Class 4 Impact Resistance
CEGS-07416 US Army Corps of
Engineers Rated-ASTM E-1592 for
180° seam
UL 580, Class 90 Wind Uplift,
Construction Number 176,180, 238,
238B, 238C, 487
Email
Contact US
Testing:
1) UL 790 Class A Fire Resistance
Rating
2) Ul 2218, Class 4 Impact Resistance
Additional Options
send paypal payments to
musiccitymetalroofing@
yahoo.com
Website Designed and Maintained for Music City Metal Roofing 2008
All content is subject to copyright
Laws

WE
DELIVER!